TAFEL
| Availability: | |
|---|---|
| Quantity: | |
The Zenergy N6N0A5 is a rechargeable NCM prismatic lithium-ion power cell with a minimum capacity of 72Ah under the specified 1C charge and discharge test. Its 1C discharge voltage plateau is 3.7V.
The manufacturer specifies a maximum 10-second discharge pulse of 576A at 25°C and at least 20% SOC. The cell is specified for electric vehicle and energy storage applications; final suitability depends on the complete pack design and operating conditions.
| Parameter | Specification |
|---|---|
| Manufacturer | Zenergy |
| Model | N6N0A5 |
| Battery Type | Rechargeable NCM lithium-ion power cell |
| Cell Structure | Prismatic cell |
| Minimum Capacity | 72Ah; 1C charge and 1C discharge |
| Discharge Voltage Plateau | 3.7V at 1C discharge |
| Reference Energy | Approx. 266.4Wh, calculated from 72Ah × 3.7V discharge plateau |
| 1C Charge Test | 72A CC-CV to 4.35V; 3.6A cutoff; 25±2°C |
| 1C Discharge Test | 72A to 2.8V; 25±2°C |
| Maximum Discharge Pulse | 576A for 10 seconds; 25°C, SOC ≥20% |
| Maximum Charge Pulse | 432A for 10 seconds; 25°C, SOC ≤70% |
| AC Impedance | ≤0.6mΩ at 1kHz, 60% SOC, beginning of life |
| Thickness | 22.85±0.5mm, including insulating film; measured under 300±20kgf pressure |
| Width | 220.32mm |
| Height | 105.20mm excluding terminals; 107.70mm including terminals |
| Cell Weight | 1.21±0.05kg |
| Operating Temperature | Above −30°C and below 55°C; charging current varies with cell temperature |
| Usable SOC Range | 5%–95% |
| Cycle Test | At least 57Ah after 3,000 cycles at 25±2°C, under the specified cycle procedure |
01. 72Ah minimum capacity: The cell is specified at a minimum of 72Ah using the manufacturer's 1C charge and discharge procedure.
02. High-power pulse capability: The maximum specified 10-second discharge pulse is 576A at 25°C and SOC ≥20%. The maximum 10-second charge pulse is 432A at 25°C and SOC ≤70%.
03. Documented cycle performance: The specification states a discharge capacity of at least 57Ah after 3,000 cycles at 25±2°C under its defined test procedure.
04. Low AC impedance: Beginning-of-life AC impedance is specified at ≤0.6mΩ when measured at 1kHz and 60% SOC.
The manufacturer identifies electric vehicles and energy storage as application areas for the N6N0A5 cell. System designers should evaluate the cell against the project's power profile, thermal management, mechanical constraints and protection requirements.
Charging current must be controlled according to cell temperature. Discharge voltage limits also vary with temperature and operating current. Refer to the complete applicable specification when designing the BMS and charging system.
Is 576A a continuous discharge rating?
No. It is the specified maximum 10-second discharge pulse at 25°C and SOC ≥20%.
What voltage is used in the 1C discharge test?
The 1C test discharges at 72A to 2.8V at 25±2°C. Other temperature-dependent limits are specified for operation.
Does the stated cell height include terminals?
The cell height is 105.20mm excluding terminals and 107.70mm including terminals.
For product selection or a quotation, provide the required quantity, pack configuration, operating current, temperature range and intended application. Confirm the applicable cell specification revision and availability for the proposed order.
Contact Misen through the inquiry form on this page to discuss your requirements and request applicable supporting documentation.